HR-GS12
Standard grating displacement sensor
Accuracy grades and RS-232 / RS-485 interfaces depend on configuration.
Browse Hurrey sensor families by measurement range, construction, and output configuration.
Family names below are transcribed from Hurrey product materials. Unverified SKU suffixes are not listed.

Accuracy grades and RS-232 / RS-485 interfaces depend on configuration.

Accuracy grades and RS-232 / RS-485 interfaces depend on configuration.

The catalog family name matches the manual range drawing; confirm interface and accuracy by configuration.

The manual drawing marks 0–12.7 mm; confirm display and interface details for the selected configuration.

The manual lists a supply air pressure of 0.16–0.2 MPa.

GT-5 and GT-10 provide 0–5 mm and 0–10 mm ranges; accuracy and resolution configurations are listed below.
Transcribed from the manual's 0–12.7, 0–25.4, and 0–32 mm range table. Grade names describe the listed performance configurations, not separate SKU suffixes.
| Range | Configuration | Full-scale accuracy | Resolution |
|---|---|---|---|
| 0–12.7 mm | Hundredth-level | ≤10 μm | 5 μm |
| Thousandth-level | ±2 μm | 1 μm | |
| Ten-thousandth-level | ≤2 μm | 0.5 μm | |
| High-precision ten-thousandth-level | ≤1.4 μm | 0.2 μm | |
| 0–25.4 mm | Hundredth-level | ≤10 μm | 5 μm |
| Thousandth-level | ±3 μm | 1 μm | |
| Ten-thousandth-level | ≤3 μm | 0.5 μm | |
| High-precision ten-thousandth-level | ≤1.8 μm | 0.2 μm | |
| 0–32 mm | Hundredth-level | ≤10 μm | 5 μm |
| Thousandth-level | ±3 μm | 1 μm | |
| Ten-thousandth-level | ≤3 μm | 0.5 μm | |
| High-precision ten-thousandth-level | ≤1.8 μm | 0.2 μm |
These values are listed by product family in the supplied materials. Confirm the exact configuration for a selected model. The GT high-precision pen-type resolution is listed as 0.1 μm in its selection data and is kept separate from the 0.2 μm high-precision option in the standard range table.
The GT series uses a high-precision pen-type construction; the table below distinguishes the standard and high-precision configurations listed in the supplied data.
| GT model | Configuration | Full-scale accuracy | Resolution | Repeat accuracy |
|---|---|---|---|---|
| GT-5 (0–5 mm) | Standard pen-type | ≤2 μm | 0.5 μm | 1 μm |
| GT-5 (0–5 mm) | High-precision pen-type | ≤1.4 μm | 0.1 μm | 0.2 μm |
| GT-10 (0–10 mm) | Standard pen-type | ≤2 μm | 0.5 μm | 1 μm |
| GT-10 (0–10 mm) | High-precision pen-type | ≤1.4 μm | 0.1 μm | 0.2 μm |