HURREY · GRATING DISPLACEMENT

Hurrey grating displacement sensors

Browse Hurrey sensor families by measurement range, construction, and output configuration.

SENSOR FAMILIES

Product families

Family names below are transcribed from Hurrey product materials. Unverified SKU suffixes are not listed.

Hurrey standard grating displacement sensor
HURREY · GRATING

HR-GS12

Standard grating displacement sensor

0–12.7 mm

Accuracy grades and RS-232 / RS-485 interfaces depend on configuration.

Hurrey standard grating displacement sensor
HURREY · GRATING

HR-GS25

Standard grating displacement sensor

0–25.4 mm

Accuracy grades and RS-232 / RS-485 interfaces depend on configuration.

Hurrey HR-GS32 grating displacement sensor
HURREY · GRATING

HR-GS32

Standard grating displacement sensor

0–32 mm

The catalog family name matches the manual range drawing; confirm interface and accuracy by configuration.

Hurrey HR-GD12 grating displacement sensor with display
HURREY · GRATING

HR-GD12

Grating displacement sensor with display

0–12.7 mm

The manual drawing marks 0–12.7 mm; confirm display and interface details for the selected configuration.

Hurrey HR-GP12 pneumatic grating displacement sensor
HURREY · GRATING

HR-GP12

Pneumatic grating displacement sensor

0–12.7 mm

The manual lists a supply air pressure of 0.16–0.2 MPa.

Hurrey GT-5 and GT-10 high-precision pen-type grating displacement sensors
HURREY · GRATING

GT-5 / GT-10

High-precision pen-type grating displacement sensor

0–5 / 0–10 mm

GT-5 and GT-10 provide 0–5 mm and 0–10 mm ranges; accuracy and resolution configurations are listed below.

SPECIFICATIONS

Standard models: accuracy and resolution options

Transcribed from the manual's 0–12.7, 0–25.4, and 0–32 mm range table. Grade names describe the listed performance configurations, not separate SKU suffixes.

RangeConfigurationFull-scale accuracyResolution
0–12.7 mmHundredth-level≤10 μm5 μm
Thousandth-level±2 μm1 μm
Ten-thousandth-level≤2 μm0.5 μm
High-precision ten-thousandth-level≤1.4 μm0.2 μm
0–25.4 mmHundredth-level≤10 μm5 μm
Thousandth-level±3 μm1 μm
Ten-thousandth-level≤3 μm0.5 μm
High-precision ten-thousandth-level≤1.8 μm0.2 μm
0–32 mmHundredth-level≤10 μm5 μm
Thousandth-level±3 μm1 μm
Ten-thousandth-level≤3 μm0.5 μm
High-precision ten-thousandth-level≤1.8 μm0.2 μm

Standard sensor data

Output interfaces
RS-232 / RS-485
Power
RS-232: DC 5 V; RS-485: DC 5–24 V
Protection rating
IP65
Data update
0–12.7 / 0–25.4 mm: 50 ms; 0–32 mm: 10 ms

Pneumatic sensor data

HR-GP12 range
0–12.7 mm
Supply air pressure
0.16–0.2 MPa
Output interfaces
RS-232 / RS-485
Protection rating
IP65

These values are listed by product family in the supplied materials. Confirm the exact configuration for a selected model. The GT high-precision pen-type resolution is listed as 0.1 μm in its selection data and is kept separate from the 0.2 μm high-precision option in the standard range table.

GT high-precision pen-type series

Models and ranges
GT-5: 0–5 mm; GT-10: 0–10 mm
Interfaces
RS-232 / RS-485
Update rate
10 ms
Protection rating
IP65

The GT series uses a high-precision pen-type construction; the table below distinguishes the standard and high-precision configurations listed in the supplied data.

RS-485 communication (as listed in the manual)

Protocol
MODBUS RTU
Default baud rate
38400
Data format
1 start bit · 8 data bits · no parity · 2 stop bits
Default address
01H
GT modelConfigurationFull-scale accuracyResolutionRepeat accuracy
GT-5 (0–5 mm)Standard pen-type≤2 μm0.5 μm1 μm
GT-5 (0–5 mm)High-precision pen-type≤1.4 μm0.1 μm0.2 μm
GT-10 (0–10 mm)Standard pen-type≤2 μm0.5 μm1 μm
GT-10 (0–10 mm)High-precision pen-type≤1.4 μm0.1 μm0.2 μm

Read the Hurrey product manual

Download the grating displacement sensor manual for dimensions, wiring, and communication details.

Open technical resources